Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Package/Case | Packaging | Series | ProductStatus | MountingType | FuseType | CurrentRating(Amps) | VoltageRating-AC | VoltageRating-DC | ResponseTime | Applications | Features | Class | ApprovalAgency | OperatingTemperature | BreakingCapacity@RatedVoltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0KLK007.TSFUSE CARTRIDGE 7A 600VAC/500VDC |
3,917 | - |
RFQ |
Datasheet |
5AG, 10mm x 38mm (Midget) | Bulk | POWR-GARD® KLK | Active | Holder | Cartridge | 7A | 600 V | 500 V | Fast Blow | Electrical, Industrial | - | - | CE, CSA, QPL, UL | - | 100kA AC, 50kA DC | |
0KLK012.TSFUSE CARTRIDGE 12A 600VAC/500VDC |
2,116 | - |
RFQ |
Datasheet |
5AG, 10mm x 38mm (Midget) | Bulk | POWR-GARD® KLK | Active | Holder | Cartridge | 12A | 600 V | 500 V | Fast Blow | Electrical, Industrial | - | - | CE, CSA, QPL, UL | - | 100kA AC, 50kA DC | |
IDSR05.6TFUSE CARTRIDGE 5.6A 600VAC/VDC |
2,828 | - |
RFQ |
Datasheet |
Cylindrical, Alarm Indicating | Bulk | POWR-GARD®, POWR-PRO® IDSR | Active | Holder | Cartridge | 5.6A | 600 V | 600 V | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | |
BK/72A-DUMMYFUSE CRTRDGE DUMMY 125VAC/300VDC |
3,791 | - |
RFQ |
Datasheet |
Cylindrical, Alarm Indicating, Dummy | Bulk | Telpower® 70 | Active | Holder | Cartridge | Dummy | 125 V | 300 V | - | Telecom | Indicating | - | UR | - | - | |
BK/72B-DUMMYFUSE CRTRDGE DUMMY 125VAC/300VDC |
2,470 | - |
RFQ |
Datasheet |
Cylindrical, Alarm Indicating, Dummy | Bulk | Telpower® 70 | Active | Holder | Cartridge | Dummy | 125 V | 300 V | - | Telecom | Indicating | - | UR | - | - | |
40NH1AM-6FUSE SQUARE 40A 500VAC RECT |
2,978 | - |
RFQ |
Rectangular, Blade | - | NH1 | Active | Holder | Square | 40A | 500 V | - | Fast Blow | - | - | NH | VDE | - | - | ||
JLLS010.TXPFUSE CARTRIDGE 10A 600VAC/300VDC |
3,481 | - |
RFQ |
Datasheet |
Cartridge, Non-Standard | Box | POWR-GARD® JLLS | Active | Bolt Mount | Cartridge | 10A | 600 V | 300 V | Fast Blow | Electrical, Industrial | - | T | CE, CSA, UL, UR | - | 200kA AC, 20kA DC | |
JLLS015.TXPFUSE CARTRIDGE 15A 600VAC/300VDC |
2,468 | - |
RFQ |
Datasheet |
Cartridge, Non-Standard | Box | POWR-GARD® JLLS | Active | Bolt Mount | Cartridge | 15A | 600 V | 300 V | Fast Blow | Electrical, Industrial | - | T | CE, CSA, UL, UR | - | 200kA AC, 20kA DC | |
JLLS025.TXPFUSE CARTRIDGE 25A 600VAC/300VDC |
3,900 | - |
RFQ |
Datasheet |
Cartridge, Non-Standard | Box | POWR-GARD® JLLS | Active | Bolt Mount | Cartridge | 25A | 600 V | 300 V | Fast Blow | Electrical, Industrial | - | T | CE, CSA, UL, UR | - | 200kA AC, 20kA DC | |
0FLQ05.6TFUSE CRTRDGE 5.6A 500VAC/300VDC |
2,096 | - |
RFQ |
Datasheet |
5AG, 10mm x 38mm (Midget) | Bulk | POWR-GARD® FLQ | Active | Holder | Cartridge | 5.6A | 500 V | 300 V | Slow Blow | Transformer Protection | - | - | CSA, UL | - | 10kA | |
0FLQ04.5TFUSE CRTRDGE 4.5A 500VAC/300VDC |
2,780 | - |
RFQ |
Datasheet |
5AG, 10mm x 38mm (Midget) | Bulk | POWR-GARD® FLQ | Active | Holder | Cartridge | 4.5A | 500 V | 300 V | Slow Blow | Transformer Protection | - | - | CSA, UL | - | 10kA | |
IDSR.600TFUSE CARTRIDGE 600MA 600VAC/VDC |
3,612 | - |
RFQ |
Datasheet |
Cylindrical, Alarm Indicating | Bulk | POWR-GARD®, POWR-PRO® IDSR | Active | Holder | Cartridge | 600mA | 600 V | 600 V | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | |
IDSR.500TFUSE CARTRIDGE 500MA 600VAC/VDC |
3,719 | - |
RFQ |
Datasheet |
Cylindrical, Alarm Indicating | Bulk | POWR-GARD®, POWR-PRO® IDSR | Active | Holder | Cartridge | 500mA | 600 V | 600 V | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | |
IDSR.800TFUSE CARTRIDGE 800MA 600VAC/VDC |
3,759 | - |
RFQ |
Datasheet |
Cylindrical, Alarm Indicating | Bulk | POWR-GARD®, POWR-PRO® IDSR | Active | Holder | Cartridge | 800mA | 600 V | 600 V | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | |
FLSR1.25TFUSE CRTRDGE 1.5A 600VAC/300VDC |
3,637 | - |
RFQ |
Datasheet |
Cartridge, Non-Standard | Bulk | POWR-GARD® FLSR | Active | Holder | Cartridge | 1.5A | 600 V | 300 V | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, QPL, UL | - | 200kA AC, 20kA DC | |
FLSR2.25TFUSE CRTRDGE 2.25A 600VAC/300VDC |
2,907 | - |
RFQ |
Datasheet |
Cartridge, Non-Standard | Bulk | POWR-GARD® FLSR | Active | Holder | Cartridge | 2.25A | 600 V | 300 V | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, QPL, UL | - | 200kA AC, 20kA DC | |
BK/GLD-4FUSE CARTRIDGE 4A 125VAC CYLINDR |
3,625 | - |
RFQ |
Datasheet |
Cylindrical, Alarm Indicator, 3AG, 1/4 x 1 1/4 | Bulk | GLD | Active | Holder | Cartridge | 4A | 125 V | - | Fast Blow | Electrical, Industrial | Indicating | - | CE, CSA, UL | - | 10kA | |
BK/GLD-1-1/2FUSE CARTRIDGE 1.5A 125VAC CYL |
3,403 | - |
RFQ |
Datasheet |
Cylindrical, Alarm Indicator, 3AG, 1/4 x 1 1/4 | Bulk | GLD | Active | Holder | Cartridge | 1.5A | 125 V | - | Fast Blow | Electrical, Industrial | Indicating | - | CE, CSA, UL | - | 10kA | |
0NLS045.TFUSE CARTRIDGE 45A 600VAC/400VDC |
2,139 | - |
RFQ |
Datasheet |
Cartridge, Non-Standard | Bulk | POWR-GARD® NLS | Active | Holder | Cartridge | 45A | 600 V | 400 V | Fast Blow | Electrical, Industrial | - | K5 | CE, CSA, UL | - | 50kA AC, 20kA DC | |
004139200FUSENH1CGFM20A400VAC |
2,486 | - |
RFQ |
- | Bulk | - | Active | - | - | 20A | 400 V | - | - | - | - | - | - | - | - |